bauzertifikate.de

Dokumentation / Schema-Referenz

dataset.json

Der experimentelle EPBD-Austauschdatensatz bzf-epbd/0.1.

BZF 0.3.0Entwurf/schema/bzf-epbd/0.1/dataset.jsonStand: .md
  • Status: Entwurf
  • Ablage: eigenständiges Austauschdokument, nicht im Projektordner
  • $id: https://bauzertifikate.de/schema/bzf-epbd/0.1/dataset.json
  • Schema laden: /schema/bzf-epbd/0.1/dataset.json (JSON Schema 2020-12)

#Beschreibung

A proposal for the data a building's energy performance certificate, renovation passport and digital building logbook exchange under Directive (EU) 2024/1275 (EPBD): every data point of its Annex V (certificate), Annex VIII (renovation passport), Annex I (the calculation's inputs and outputs), Annex III (life-cycle GWP) and Articles 12, 16, 19, 20(8), 22 and 24, plus the identifiers that link a building to the cadastre, the land register and a national building register (Art. 22(7)). Field descriptions name the clause they answer. Figures are per m² of the reference floor area and year unless they say otherwise. Shares are fractions (0 to 1), money is in currency, VAT included, and free text (labels, reasons, notes) is in language. Keys and listed values are English; a value national to one country carries its code, <country>:<value> (de:isfp), one the EPBD or an EU or international standard defines stays bare (nzeb). Times are RFC 3339 with the local offset (Z only for a time kept in UTC). Version 0.1 carries a building's current certificate, passport and assessment, the last issued; earlier ones stay with the registers and logbooks that hold them. Every object keeps fields it doesn't list, so a reader of this version reads a newer minor one (format). It can be written from and read into the open building format bzf (https://bauzertifikate.de/schema/bzf/1/); MAPPINGS.md in the specification lists where each data point lies there. Status: proposal, offered to CEN/TC 442/WG 13 and its DIN mirror committee for the logbook's core data template. Licence: CC0 1.0.

#Das Dokument

Feld Typ Beschreibung
format Pflicht string This format and its version, bzf-epbd/<major>.<minor>; this schema's is 0.1. A newer minor only adds fields and values, so a reader of 0.1 reads every 0.x file and names what it doesn't know rather than dropping it unsaid. Another major version is another format and isn't read as this one. (Muster ^bzf-epbd/0\.[0-9]+$)
written object Who wrote the file, when and from which project state, so a register or logbook can tell two files of one building apart and trace one back to where it came from. It describes the file, not the building: a reader keeps it with the file, not in the building's record.
written.time string (date-time) When the file was written.
written.app string The software that wrote it: "bauzertifikate Aufmaß".
written.appVersion string Its version.
written.kernelVersion string The version of the calculation kernel that worked out what is derived (the envelope).
written.project string The id of the project it was written from (in bzf, project.json id), the same in every file of that project.
written.revision string The project state it was written from: in bzf the revision's SHA-256 (revision.json), so the file is traced to the exact data it shows.
language Pflicht string The language of the file's free text, as a BCP 47 tag: "de", "fr-BE". (Muster ^[a-z]{2,3}(-[A-Za-z0-9]{1,8})*$)
currency Pflicht string The currency of every amount of money in the file, ISO 4217: "EUR". (Muster ^[A-Z]{3}$)
building Pflicht building –
envelope envelope –
systems Liste von system The technical building systems (Art. 2(6), Art. 16(1), Annex I 4(b) to (f), (k), 5; Annex V 2(a), (i) to (m), (r), (s)).
consumption Liste von metered Metered energy consumption by carrier and period (Annex V 2(q), Annex I 1, Art. 22(1)).
certificate certificate –
passport passport –
smartReadiness smartReadiness –
inspections Liste von inspection Inspections of heating, ventilation and air-conditioning systems over 70 kW (Art. 23, Art. 24(3)).

#Typen

Die Typen dieses Schemas, auf die seine Felder verweisen.

#knownOrNewer

One of the values a field lists, or a newer one, kept. National values carry their country, <country>:<value>. Only strings: bzf also keeps newer values that are objects, which this version doesn't carry.

Typ: string

#when

When it was issued: an RFC 3339 time with its offset, or a date (ISO 8601) where only the day is known.

Typ: string (date-time) oder string (date)

#carrier

An energy carrier.

Typ: eins von oder knownOrNewer

#service

An energy use as Annex V and Annex I 2 list them.

Typ: eins von oder knownOrNewer

#heatNetwork

A connection to a district heating or cooling network, or its potential: connected, available (a network is there to connect to), planned, none, unknown.

Typ: eins von oder knownOrNewer

#identifier

An id in someone else's register: the scheme that issued it and its value. National schemes carry their country: for a building de:alkis (the German cadastre), de:land-register, <country>:building-id (a national building register, once one exists); for a registration the register, de:dibt, de:bafa.

Feld Typ Beschreibung
scheme Pflicht string –
value Pflicht string –

#registration

Where something issued was registered or uploaded: the register as scheme, the number it got as value, and when.

Typ: identifier und object

#building

Who and where the building is. At least one of identifiers, address and location, so a register or logbook can link the record to its building.

Feld Typ Beschreibung
identifiers Liste von identifier The ids the building has in other registers, so a database links it to the cadastre, the land register and logbooks (Art. 22(7)). The directive names no building identifier. (mindestens 1 Einträge)
address object Its postal address (national, e.g. § 85 Abs. 1 Nr. 5 GEG/GModG).
address.street string –
address.number string –
address.postcode string –
address.city string –
address.country string ISO 3166-1 alpha-2: "DE". (Muster ^[A-Z]{2}$)
location object Where it lies, for the outdoor climate, solar exposure and heat planning (Annex I 4(g), Art. 22(3)).
location.crs Pflicht string A projected coordinate reference system by its EPSG code: "EPSG:25832" (ETRS89 / UTM 32N); across borders EPSG:3035 (ETRS89 / LAEA Europe).
location.easting Pflicht number The CRS's first axis, m.
location.northing Pflicht number The CRS's second axis, m.
year integer Year of construction.
use eins von oder knownOrNewer Residential, non-residential or both.
category eins von oder knownOrNewer Its category as Annex I 6 lists them.
dwellings integer Number of dwellings. (≥ 0)
n50 number Air changes at 50 Pa, 1/h, where measured (Annex I 4(e)). (≥ 0)
thermalBridges object How thermal bridges are accounted for (Annex I 4(a)(v)): default (a flat allowance on the envelope's U-values), reduced (the details follow a national catalogue of good practice, so a smaller allowance applies), detailed (each bridge calculated); with the allowance, where one applies.
thermalBridges.kind eins von oder knownOrNewer –
thermalBridges.deltaU number The allowance on the envelope's U-values, W/(m²·K). (≥ 0)
seismic object Its seismic safety, where relevant (Annex VIII 2(f)).
seismic.zone string The earthquake zone of the national annex to EN 1998-1.
seismic.note string What is known of the structure's resistance.

#envelope

The thermal envelope as worked out from the building's geometry: part of the data needed for the calculation uploaded with a certificate (Art. 20(8), Annex I 4(a), (g), (h)), and Annex V 2(e) to (g).

Feld Typ Beschreibung
heatedVolume Pflicht number Heated gross volume, m³. (≥ 0)
netFloorArea Pflicht number Net floor area of the heated spaces, inside their walls, m²: the useful floor area of Art. 2(51) as the geometry gives it. The figures' own reference area is figures.area. (≥ 0)
area Pflicht number Envelope area, m². (≥ 0)
parts Liste von object The envelope by element, what lies behind it and the direction it faces, net of openings.
parts[].kind Pflicht eins von oder knownOrNewer –
parts[].boundary Pflicht eins von oder knownOrNewer –
parts[].azimuth number Compass bearing of the outward normal in degrees clockwise from north (0 north, 90 east), in steps of 45°; absent for a horizontal part. (≥ 0, < 360)
parts[].area Pflicht number m². (≥ 0)
meanUOpaque number Average U-value of the opaque elements, W/(m²·K) (Annex V 2(e)). (≥ 0)
meanUTransparent number Average U-value of the transparent elements, W/(m²·K) (Annex V 2(f)). (≥ 0)
commonWindow string Type of the most common transparent element (Annex V 2(g)): "insulatingDouble", "triple".
meanG number Average total solar energy transmittance of the windows (Annex I 4(a)(iii), 4(h)). (≥ 0, ≤ 1)
shadedShare number Share of the windows' area with solar protection (Annex I 4(h)). (≥ 0, ≤ 1)

#system

A technical building system.

Feld Typ Beschreibung
id string Its id where it came from, so data coming back finds it.
kind Pflicht eins von oder knownOrNewer –
type string Its type within its kind: a boiler condensing, a heat pump outdoorAir, a thermal storage hotWater or buffer, emitters underfloor, automation indoorQualitySensors (Annex V 2(i)) or indoorQualityControls (Annex V 2(j)), a charging point ac or dc.
services Liste von service The energy uses it serves.
carrier carrier The energy carrier it takes in.
output number Rated output, kW (Annex V 2(a): size of generator). (≥ 0)
peakPower number A PV array's peak power, kWp (Annex I 4(c)). (≥ 0)
area number Collector or module area, m². (≥ 0)
year integer Year installed.
endOfLife integer Year its lifespan is expected to end (Annex V 2(m), Art. 16(1), Art. 19(9)).
signals boolean Whether it can react to external signals and adjust its consumption.
flowTemperature number Design supply temperature of a distribution or emitters, °C.
efficiency number Seasonal efficiency of a generator, as a fraction (Art. 16(1)). (> 0)
scop number A heat pump's seasonal coefficient of performance, or its seasonal performance factor as measured. (> 0)
seer number A cooling unit's seasonal energy efficiency ratio (Annex I 4(d), Art. 16(1)). (> 0)
power number Rated electrical input power, kW: built-in lighting (Annex I 4(f)), fans, pumps. (≥ 0)
airflow number A ventilation unit's design air volume flow, m³/h (Annex I 4(e)). (≥ 0)
specificFanPower number A ventilation unit's specific fan power, W/(m³/h). (≥ 0)
insulation eins von oder knownOrNewer How a distribution's pipes or a thermal storage are insulated (Annex I 4(b)).
standingLoss number A thermal storage's standing heat loss, kWh a day. (≥ 0)
heatRecovery number A ventilation unit's heat recovery efficiency (Annex I 4(e)). (≥ 0, ≤ 1)
automationClass eins von oder knownOrNewer Building automation and control class of EN ISO 52120-1 (Annex I 4(k)).
factors object Primary energy and emission factors of what it takes in, where they are its own: a district heating network's (Annex V 2(s)).
factors.primary number Primary energy factor (non-renewable part). (≥ 0)
factors.emission number g CO₂-eq/kWh. (≥ 0)
factors.source string Who states them.
count integer How many alike it stands for: recharging points (Annex V 2(k)). (≥ 1)
energy number A battery's usable capacity, kWh: an amount of energy, not a volume (Annex V 2(l)). (≥ 0)
volume number A thermal storage's volume, litres, not m³ (Annex V 2(l)). (≥ 0)

#metered

Metered consumption of one carrier over one period.

Feld Typ Beschreibung
carrier Pflicht carrier An energy carrier.
services Liste von service The energy uses the meter covers.
from Pflicht string (date) First day.
to Pflicht string (date) Last day, inclusive.
amount Pflicht number (≥ 0)
unit Pflicht string kWh, m3, l, kg, …

#figures

The figures of a certificate, a renovation step or a target, as the issuing method calculated or measured them (the certificate's basis and method).

Feld Typ Beschreibung
class string Energy performance class (Annex V 1(a); Annex VIII 1(e)(v) per step), on classScale.
classScale eins von oder knownOrNewer The scale class and emissionClass are on: eu for the harmonised A to G of Art. 19(2), or a national one, de:geg (A+ to H).
primaryEnergy number Annual primary energy use, kWh/(m²·a) (Annex V 1(b)): the non-renewable part where the method separates it, else the total. A writer that has both also fills primaryEnergyTotal.
primaryEnergyTotal number Total primary energy, kWh/(m²·a) (Annex I 3).
primaryEnergyRenewable number Renewable primary energy, kWh/(m²·a) (Annex I 3).
finalEnergy number Annual final energy use, kWh/(m²·a) (Annex V 1(c)).
energyNeed number Calculated energy needs, kWh/(m²·a) (Annex V 1, second paragraph (c)).
emissions number Operational greenhouse gas emissions, kg CO₂-eq/(m²·a) (Annex V 1(e)).
emissionClass string Greenhouse gas emission class (Annex V 2(b)), on classScale.
renewableShare number Renewable energy produced on site as a fraction of the building's final energy use (Annex V 1(d); Annex VIII 1(g) after renovation); above 1 where it produces more than it uses. (≥ 0)
renewableProduction number Renewable energy produced on site, kWh a year (Annex V 1, second paragraph (b)); its carrier and source follow from the producing systems. (≥ 0)
selfConsumption number Share of the renewable energy produced on site the building uses itself (Annex VIII 1(g)). (≥ 0, ≤ 1)
lifeCycleGwp number Life-cycle global warming potential, kg CO₂-eq/m² of useful floor area over 50 years (Annex V 1(e), Art. 7(2)).
lifeCycleGwpStages Zuordnung string → number The same per EN 15978 module (Annex III): "A1-A3", "A4-A5", "B1-B7", "C1-C4", "D".
carbonRemovals number Carbon removals by temporary storage in or on the building, kg CO₂-eq/m² (Annex V 2(c)).
pm25 number Operational PM2.5 emissions, g/(m²·a) (Annex V 2(t)). (≥ 0)
uses Zuordnung string → object The figures per energy use: heating, cooling, hotWater, ventilation, lighting (Annex V 2(a), Annex I 2).
energyCosts number Energy costs a year at the stated prices, in currency (Annex VIII 1(e)(iv)).
standard string A standard reached (Annex VIII 2(b)(ii)): nzeb, zeb, or a national one, de:effizienzhaus-70.
area number The reference floor area the figures are per, m² (Art. 2(52)); with it the annual totals in kWh (Annex V 1, second paragraph (a)). (≥ 0)
areaKind eins von oder knownOrNewer Which area area is: referenceFloorArea (Art. 2(52)), usefulFloorArea (Art. 2(51)), netFloorArea, grossFloorArea, livingArea.
areaKindNational string The area's national definition: de:AN (GEG Gebäudenutzfläche), de:NGF (DIN 277 net floor area), de:WoFlV (living area).
references object The reference values stated beside the figures, kWh/(m²·a) of primary energy, as they apply to this building (Art. 19(1), Annex VIII 2(b)(ii)).
references.minimumRequirement number Minimum energy performance requirement.
references.meps number Minimum energy performance standard.
references.nzeb number Nearly zero-energy requirement.
references.zeb number Zero-emission requirement.

#issue

Something issued: when, until when, where registered.

Feld Typ Beschreibung
issued Pflicht when When it was issued.
validUntil string (date) The last day it is valid, inclusive.
registrations Liste von registration Where something issued was registered or uploaded.

#inspection

An inspection report (Art. 23, 24): what was inspected and what came of it.

Typ: issue und object

#contact

A one-stop shop for renovation advice (Annex V 1(f), Annex VIII 1(j)).

Feld Typ Beschreibung
name string –
url string –
email string –

#certificate

The energy performance certificate issued last (Art. 19, Annex V); validUntil at most ten years on (Art. 19(13)), registrations its numbers in registers and databases (Art. 20(8)).

Typ: issue und object

#passport

The renovation passport issued last (Art. 12, Annex VIII), or the roadmap before it is issued.

Feld Typ Beschreibung
issued when Absent while the roadmap is not issued.
registrations Liste von registration Where it was uploaded (Art. 12(7)).
visit string (date) The on-site visit it rests on (Art. 12(4)).
current figures The building's current performance (Annex VIII 1(a)).
target figures What the roadmap aims at, renewable share and self-consumption included (Annex VIII 1(g)).
targetYear integer –
heatNetwork heatNetwork Potential connection to an efficient district heating or cooling system (Annex VIII 1(f)).
assumptions object The calculation's assumptions (Annex VIII 1(e)(iv), 2(c)(vi)).
assumptions.prices Liste von object Energy prices per carrier, in currency.
assumptions.prices[].carrier Pflicht carrier An energy carrier.
assumptions.prices[].perKWh number Price per kWh of final energy. (≥ 0)
assumptions.prices[].perYear number Fixed price a year (a standing charge). (≥ 0)
assumptions.increase number Price increase a year, as a fraction.
assumptions.method string The calculation method.
assumptions.priceSource string –
oneStopShop contact A one-stop shop for renovation advice (Annex V 1(f), Annex VIII 1(j)).
steps Liste von step The steps of the staged renovation in their order, past renovations first (Annex VIII 1(b), 2(e)).

#step

A step of a renovation roadmap, or a certificate's recommendation.

Feld Typ Beschreibung
id string –
label Pflicht string –
year integer Year planned or done (Annex VIII 2(a)).
until integer Last year of the range planned.
trigger string The occasion it waits for instead of a year.
duration number Time it takes to carry out, weeks of seven days (Annex VIII 2(b)(v)). (≥ 0)
status eins von oder knownOrNewer planned, done (a past renovation, Annex VIII 2(e)) or declined by the owner. Absent: planned.
rationale string Why it comes in this place (Annex VIII 1(d)).
measures Liste von object –
measures[].label Pflicht string –
measures[].description string –
measures[].options Liste von string Technology and material options.
measures[].requirements Liste von string Technical, safety and low-temperature conditions (Annex VIII 2(c)(iii), (v)).
measures[].trades Liste von string Typical trades (Annex VIII 2(c)(i)).
measures[].advantages Liste von string What speaks for it (Annex VIII 2(b)(i)).
measures[].disadvantages Liste von string What speaks against it (Annex VIII 2(b)(i)).
measures[].lifetime integer Expected service life, whole years (Annex VIII 2(b)(vii)). (≥ 0)
measures[].funding Liste von object Funding available, with links (Annex VIII 1(i)).
measures[].funding[].programme Pflicht string –
measures[].funding[].url string –
measures[].costs object Estimated costs in currency (Annex VIII 2(b)(iii), (vii)); commercial, given only where its holder shares them.
measures[].costs.investment number The whole investment.
measures[].costs.anywayCosts number The part of the investment that would be due anyway, as repair or replacement, without the renovation.
measures[].costs.maintenanceYearly number What keeping it in order costs a year once done (Annex VIII 2(b)(vii)).
measures[].costs.funding number The funding expected.
figures figures The building's figures after the step (Annex VIII 1(e)(ii) to (v); Art. 19(7)).

#smartReadiness

The smart readiness assessment issued last (Art. 15, Annex V 2, last paragraph).

Feld Typ Beschreibung
issued Pflicht when When it was issued.
value number The indicator as a fraction, its percentage divided by 100. (≥ 0, ≤ 1)

#Lesen und prüfen

Die Beschreibungen stammen unverändert aus dem Schema und sind wie die Spezifikation englisch. Jedes Objekt lässt weitere Felder zu (additionalProperties: true): Programme bewahren Felder und Werte, die sie nicht kennen. Wie ein Dokument geprüft wird, steht im Schnellstart.

Grundlage: BZF 0.3.0 von Bauzertifikate contributors. Spezifikation und Dokumentation: CC BY 4.0, Schemas und Beispiele: CC0 1.0. Maßgeblich ist der englische Text der Spezifikation.